Question 1
Link to questionConsider a scenario where a Configuration Management Lead Implementer for a firm developing safety-critical medical devices discovers that a critical firmware update, intended for release next quarter, has been subtly altered by a developer without following the established change control procedures. This alteration, though seemingly minor, could potentially impact the device\'s diagnostic accuracy. What is the most immediate and critical action the Configuration Management Lead Implementer must take to uphold the principles of ISO 10007:2017 in this situation?
Formally document the unauthorized change and initiate the established deviation control process for impact assessment and disposition.
Immediately revert the firmware to the last approved baseline and conduct a root cause analysis of the developer's actions.
Inform senior management about the unauthorized modification and await their directive on how to proceed with the firmware.
Instruct the developer to correct the firmware according to the proper procedures before any further action is taken.
Show answer and explanation
Correct answer
Formally document the unauthorized change and initiate the established deviation control process for impact assessment and disposition.
The core principle of configuration management is to establish and maintain the integrity of a product or system throughout its lifecycle by controlling and documenting its functional and physical characteristics. This involves identifying configuration items (CIs), establishing baselines, managing changes, and verifying and auditing the configuration. When a deviation from an established baseline occurs, such as the discovery of an unauthorized modification to a critical software component in a regulated aerospace system, the immediate and most crucial step, as per ISO 10007:2017 principles, is to initiate a formal deviation control process. This process ensures that the deviation is properly documented, analyzed for its impact, and that a decision is made regarding its correction or acceptance. The goal is to prevent uncontrolled changes from propagating and compromising the system\'s integrity and compliance. Therefore, the primary action is to formally document and report the deviation to the appropriate authority for evaluation and disposition, which aligns with the robust change control and baseline management mandated by the standard. This proactive approach safeguards against potential safety hazards and regulatory non-compliance, which are paramount in industries governed by strict quality and safety standards.